Investigation into using liquid crystal thermography as primary temperature measurement technique for obtaining local wall temperatures and heat transfer coefficients in tube-in-tube heat exchangers

The feasibility of obtaining local wall temperatures by using liquid crystal thermography (LCT) in a counter-flow tube-in-tube heat exchanger was investigated. Local annulus-side heat transfer coefficients at the inlet and thermodynamically and hydrodynamically underdeveloped regions were also obtai...

Full description

Bibliographic Details
Main Author: Van der Westhuizen, Jacob E.
Other Authors: Dirker, Jaco
Language:en
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/2263/45967
Van der Westhuizen, JE 2015, Investigation into using liquid crystal thermography as primary temperature measurement technique for obtaining local wall temperatures and heat transfer coefficients in tube-in-tube heat exchangers, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/45967>