Embedded Reference Electrodes for Corrosion Potential Monitoring, Electrochemical Characterization, and Controlled-Potential Cathodic Protection
A thin wire Ag/AgCl reference electrode was prepared using 50 μm Ag wire in dilute FeCl3. The wire was embedded beneath the polyurethane topcoat of two sacrificial coating systems to monitor their corrosion potential. This is the first report of a reference electrode embedded between organic coating...
Main Author: | |
---|---|
Format: | Others |
Published: |
North Dakota State University
2017
|
Subjects: | |
Online Access: | https://hdl.handle.net/10365/26489 |