Embedded Reference Electrodes for Corrosion Potential Monitoring, Electrochemical Characterization, and Controlled-Potential Cathodic Protection

A thin wire Ag/AgCl reference electrode was prepared using 50 μm Ag wire in dilute FeCl3. The wire was embedded beneath the polyurethane topcoat of two sacrificial coating systems to monitor their corrosion potential. This is the first report of a reference electrode embedded between organic coating...

Full description

Bibliographic Details
Main Author: Merten, Bobbi Jo Elizabeth
Format: Others
Published: North Dakota State University 2017
Subjects:
Online Access:https://hdl.handle.net/10365/26489