High temperature deformaton at dissimilar metal interfaces

A study has been made of the relative importance of the many possible factors which could be determining failure of austenitic-ferritic dissimilar metal welds, during service within steam boilers in electricity generating plant. In service this type of localised intergranular failure occurs in the h...

Full description

Bibliographic Details
Main Author: Chilton, I. J.
Published: Swansea University 1982
Subjects:
669
Online Access:http://ethos.bl.uk/OrderDetails.do?uin=uk.bl.ethos.636248