Modeling of the Thermal Output of a Flat Plate Solar Collector
Traditionally, energy capture by non-concentrating solar collectors is calculated using the Hottel-Whillier Equation (HW): Q(u)=A(c)*F(r)*S-A(c)*F(r)*U(l)*(T(fi)-Tₐ), or its derivative: Q(u)=A(c)*F(r)*S-A(c)*F(r)*U(l)*((T(fi)-T(fo))/2-Tₐ). In these models, the rate of energy capture is based on the...