On the influence of effective stress and micro-structure on suffusion and suffosion
The research presented within this thesis covers the development of a flexible wall permeameter, and a parametric laboratory investigation of the factors influencing seepage-induced internal instability in gap-graded granular materials. A flexible wall permeameter comprising a double-walled triaxial...