The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB
碩士 === 中華大學 === 機械工程學系碩士班 === 103 === The purpose of this study is to find out the effect of various organic additives at specific concentration on filling the blind micro-via in PCB. The size of blind micro-via used in this study is 4 mil. In experiment, we used the high copper low acid solution as...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2015
|
Online Access: | http://ndltd.ncl.edu.tw/handle/29049668160271780146 |
id |
ndltd-TW-103CHPI5489009 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103CHPI54890092017-02-19T04:30:57Z http://ndltd.ncl.edu.tw/handle/29049668160271780146 The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB 有機添加劑對 PCB 板中之微米級盲孔填孔能力之影響 Shao-Tang Ding 丁紹堂 碩士 中華大學 機械工程學系碩士班 103 The purpose of this study is to find out the effect of various organic additives at specific concentration on filling the blind micro-via in PCB. The size of blind micro-via used in this study is 4 mil. In experiment, we used the high copper low acid solution as a base of chemical solution, In filling the blind micro-via of electroplating processes, the current density of 20 ASF and the plating duration of 60 minutes were used. The filling performance was judged according to the industry demand. In this study, several combinations were utilized by using various molecular weight of suppressors, note as A3+A4, A2+A4 and A1+A4. The leveler used in this study was noted as L and the brightener used in this study was noted as B. In A1+A4 system, the best filling performance was found when the chemical composition was composed of 7.5 (mL/L) A1, 7.5 (mL/L) A4, 3 (mL/L) L1, 0.85 (mL/L) L2 and 2.5 (mL/L) B1. The results show that ST (Surface Thickness) can be measured to be 14μm, the dimple can be measured to be 7.6μm. The filling performance was about 90.1%. In A2+A4 system, the best filling performance was found when the chemical composition was composed of 8.5 (mL/L) A2, 8.5 (mL/L) A4, 3.5 (mL/L) L1, 1 (mL/L) L2 and 4.5 (mL/L) B1. The results show that ST can be measured to be 8.45μm, the dimple can be measured to be 9.9μm. The filling performance was about 89.1%. In A3+A4 system, the best filling performance was found when the chemical composition was composed of 8.5 (mL/L) A3, 8.5 (mL/L) A4, and 3 (mL/L) B1. The dimple also can be measured to be 11.5μm when the chemical composition was composed of 5.5 (mL/L) L1 or 10.5 (mL/L) L1. The results show that ST can be measured to be 18.8μm, the filling performance was about 90.1% when L1 was 5.5 (mL/L). The results show that ST can be measured to be 14.7μm, the filling performance was about 87.1% when L1 was 10.5 (mL/L). In the consumption of additive in system A1+A4, it was found that the consumption rate of L1+L2 was measured to be 81.6%. The consumption rate of B1 was measured to be 58%. While, the consumption rate of suppressor A1+A4 was measured to be 28 %. All the results were measured in one hour of electroplating processes. Yu-Li Lin Shinn-Horng Yeh 林育立 葉信宏 2015 學位論文 ; thesis 42 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中華大學 === 機械工程學系碩士班 === 103 === The purpose of this study is to find out the effect of various organic additives at specific concentration on filling the blind micro-via in PCB. The size of blind micro-via used in this study is 4 mil. In experiment, we used the high copper low acid solution as a base of chemical solution, In filling the blind micro-via of electroplating processes, the current density of 20 ASF and the plating duration of 60 minutes were used. The filling performance was judged according to the industry demand. In this study, several combinations were utilized by using various molecular weight of suppressors, note as A3+A4, A2+A4 and A1+A4. The leveler used in this study was noted as L and the brightener used in this study was noted as B.
In A1+A4 system, the best filling performance was found when the chemical composition was composed of 7.5 (mL/L) A1, 7.5 (mL/L) A4, 3 (mL/L) L1, 0.85 (mL/L) L2 and 2.5 (mL/L) B1. The results show that ST (Surface Thickness) can be measured to be 14μm, the dimple can be measured to be 7.6μm. The filling performance was about 90.1%.
In A2+A4 system, the best filling performance was found when the chemical composition was composed of 8.5 (mL/L) A2, 8.5 (mL/L) A4, 3.5 (mL/L) L1, 1 (mL/L) L2 and 4.5 (mL/L) B1. The results show that ST can be measured to be 8.45μm, the dimple can be measured to be 9.9μm. The filling performance was about 89.1%.
In A3+A4 system, the best filling performance was found when the chemical composition was composed of 8.5 (mL/L) A3, 8.5 (mL/L) A4, and 3 (mL/L) B1. The dimple also can be measured to be 11.5μm when the chemical composition was composed of 5.5 (mL/L) L1 or 10.5 (mL/L) L1. The results show that ST can be measured to be 18.8μm, the filling performance was about 90.1% when L1 was 5.5 (mL/L). The results show that ST can be measured to be 14.7μm, the filling performance was about 87.1% when L1 was 10.5 (mL/L).
In the consumption of additive in system A1+A4, it was found that the consumption rate of L1+L2 was measured to be 81.6%. The consumption rate of B1 was measured to be 58%. While, the consumption rate of suppressor A1+A4 was measured to be 28 %. All the results were measured in one hour of electroplating processes.
|
author2 |
Yu-Li Lin |
author_facet |
Yu-Li Lin Shao-Tang Ding 丁紹堂 |
author |
Shao-Tang Ding 丁紹堂 |
spellingShingle |
Shao-Tang Ding 丁紹堂 The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB |
author_sort |
Shao-Tang Ding |
title |
The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB |
title_short |
The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB |
title_full |
The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB |
title_fullStr |
The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB |
title_full_unstemmed |
The Effect of Organic Additives on The Ability of Filling The Blind Micro-via in PCB |
title_sort |
effect of organic additives on the ability of filling the blind micro-via in pcb |
publishDate |
2015 |
url |
http://ndltd.ncl.edu.tw/handle/29049668160271780146 |
work_keys_str_mv |
AT shaotangding theeffectoforganicadditivesontheabilityoffillingtheblindmicroviainpcb AT dīngshàotáng theeffectoforganicadditivesontheabilityoffillingtheblindmicroviainpcb AT shaotangding yǒujītiānjiājìduìpcbbǎnzhōngzhīwēimǐjímángkǒngtiánkǒngnénglìzhīyǐngxiǎng AT dīngshàotáng yǒujītiānjiājìduìpcbbǎnzhōngzhīwēimǐjímángkǒngtiánkǒngnénglìzhīyǐngxiǎng AT shaotangding effectoforganicadditivesontheabilityoffillingtheblindmicroviainpcb AT dīngshàotáng effectoforganicadditivesontheabilityoffillingtheblindmicroviainpcb |
_version_ |
1718415564944179200 |