The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel

碩士 === 遠東科技大學 === 機械工程研究所在職專班 === 101 === The purpose of this paper is to perform the heat dissipation design, simulation and investigation for the boost circuit board, which was placed within the three-dimensional channel, by applying numerical simulation method. First, three cooling modes includin...

Full description

Bibliographic Details
Main Authors: Cheng, Chin-Chuan, 鄭進全
Other Authors: Chen, Ming-Chiou
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/98761414497338503379
id ndltd-TW-101FEC00489004
record_format oai_dc
spelling ndltd-TW-101FEC004890042017-01-14T04:15:03Z http://ndltd.ncl.edu.tw/handle/98761414497338503379 The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel 三維渠道內部電子元件之對流散熱研究 Cheng, Chin-Chuan 鄭進全 碩士 遠東科技大學 機械工程研究所在職專班 101 The purpose of this paper is to perform the heat dissipation design, simulation and investigation for the boost circuit board, which was placed within the three-dimensional channel, by applying numerical simulation method. First, three cooling modes including natural convection, force convection and special cooling assembly are planed and designed to reduce the temperature of electronic components on the boost circuit board. Then, the influences on the temperature of electronic components due to the change design parameters will be investigated by executing a serious of heat dissipation testing for different cooling modes respectively. Furthermore, the feasibility of cooling and optimum design parameters for each cooling mode, also the optimum cooling mode will be found after comparing the optimum design results of cooling modes. The study results show that if the temperature of power transistor(MOS) be used for evaluation criteria of cooling effective, the "special assembly" cooling design has the cooling efficiency (the MOS’s temperature can dropped to 33℃); secondly was “forced convection” (the MOS’s temperature can dropped to 45.4℃); worst was "natural convection",(the MOS’s temperature only can dropped to 73.5℃ and unable to meet the cooling requirements that the MOS’s temperature under 65 ℃). Besides, if the overall temperature of boost circuit board be used for evaluation criteria of cooling effective, the “forced convection” design mode has the best overall cooling effect, it can drop the temperature of all the electric components (including transformers) to below 50℃. Finally, if the main considerations of cooling design is based on the heat dissipation demand of the converter circuit and operational stability and reliability of cooling system, the "special assembly" will be the best choose. Chen, Ming-Chiou 沈銘秋 2013 學位論文 ; thesis 87 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 遠東科技大學 === 機械工程研究所在職專班 === 101 === The purpose of this paper is to perform the heat dissipation design, simulation and investigation for the boost circuit board, which was placed within the three-dimensional channel, by applying numerical simulation method. First, three cooling modes including natural convection, force convection and special cooling assembly are planed and designed to reduce the temperature of electronic components on the boost circuit board. Then, the influences on the temperature of electronic components due to the change design parameters will be investigated by executing a serious of heat dissipation testing for different cooling modes respectively. Furthermore, the feasibility of cooling and optimum design parameters for each cooling mode, also the optimum cooling mode will be found after comparing the optimum design results of cooling modes. The study results show that if the temperature of power transistor(MOS) be used for evaluation criteria of cooling effective, the "special assembly" cooling design has the cooling efficiency (the MOS’s temperature can dropped to 33℃); secondly was “forced convection” (the MOS’s temperature can dropped to 45.4℃); worst was "natural convection",(the MOS’s temperature only can dropped to 73.5℃ and unable to meet the cooling requirements that the MOS’s temperature under 65 ℃). Besides, if the overall temperature of boost circuit board be used for evaluation criteria of cooling effective, the “forced convection” design mode has the best overall cooling effect, it can drop the temperature of all the electric components (including transformers) to below 50℃. Finally, if the main considerations of cooling design is based on the heat dissipation demand of the converter circuit and operational stability and reliability of cooling system, the "special assembly" will be the best choose.
author2 Chen, Ming-Chiou
author_facet Chen, Ming-Chiou
Cheng, Chin-Chuan
鄭進全
author Cheng, Chin-Chuan
鄭進全
spellingShingle Cheng, Chin-Chuan
鄭進全
The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel
author_sort Cheng, Chin-Chuan
title The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel
title_short The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel
title_full The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel
title_fullStr The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel
title_full_unstemmed The Study of Convection Heat Dissipation of Electric Parts in the Three-Dimensional Channel
title_sort study of convection heat dissipation of electric parts in the three-dimensional channel
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/98761414497338503379
work_keys_str_mv AT chengchinchuan thestudyofconvectionheatdissipationofelectricpartsinthethreedimensionalchannel
AT zhèngjìnquán thestudyofconvectionheatdissipationofelectricpartsinthethreedimensionalchannel
AT chengchinchuan sānwéiqúdàonèibùdiànziyuánjiànzhīduìliúsànrèyánjiū
AT zhèngjìnquán sānwéiqúdàonèibùdiànziyuánjiànzhīduìliúsànrèyánjiū
AT chengchinchuan studyofconvectionheatdissipationofelectricpartsinthethreedimensionalchannel
AT zhèngjìnquán studyofconvectionheatdissipationofelectricpartsinthethreedimensionalchannel
_version_ 1718408071493976064