A study of applying value engineering to improve the energy management system of fresh central kitchen

碩士 === 國立臺灣大學 === 土木工程學研究所 === 99 === Central kitchen, snack street, and restaurant are high power demand facilities. With high power consumptions, global warming situation could be deteriorated. A kilowatt〈kW-hr〉saving would be equivalent a 0.636 kg CO2 emission reduction. From a corporate point of...

Full description

Bibliographic Details
Main Authors: Yi-Kun Chen, 陳一坤
Other Authors: M.T. Wang
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/21980708344015639846
id ndltd-TW-099NTU05015059
record_format oai_dc
spelling ndltd-TW-099NTU050150592015-10-16T04:02:50Z http://ndltd.ncl.edu.tw/handle/21980708344015639846 A study of applying value engineering to improve the energy management system of fresh central kitchen 價值工程應用於生鮮廚房能源管理系統之改善研究 Yi-Kun Chen 陳一坤 碩士 國立臺灣大學 土木工程學研究所 99 Central kitchen, snack street, and restaurant are high power demand facilities. With high power consumptions, global warming situation could be deteriorated. A kilowatt〈kW-hr〉saving would be equivalent a 0.636 kg CO2 emission reduction. From a corporate point of view, energy saving in these facilities can not only be beneficial to environment protection, but also good for energy cost reduction, and consequently, enhancing the competitiveness of the corporation. In order to maintain technical advantage and reduce operation costs, chain restaurants set up fresh central kitchen to control their food quality and transportation cost. Other than the frozen facility, electric power requirement of ventilation system is high, which can directly affect the operation costs of the kitchen. In this respect, value engineering (VE) technique can be used to analyze the operation of a fresh central kitchen. Under the budget constraint, energy efficiency, energy saving and environment protection issues can be considered in the analysis in order to reduction overall business costs.. A specific fresh central kitchen case is used in this study to demonstrate the procedure of a VE analysis for ventilation improvement project that can effectively reduce the operation cost of the facility. The investigating works involved include ventilation testing, current situation and engineering difficulty assessment. Study results suggest that using power electronics inverter with exhaust fan and additional devices could improve overall performance and enhance energy management flexibility. Past operation practice focused only on the exhaust air volume, and paid little attention to the amount and adequacy of intake air. Appropriateness of the equipment types is another important issue that is yet to be addressed. In order to enhance energy efficiency and reach the goal of flexible energy management for achieving energy saving and carbon reduction, adding supplementary components in energy management system and inverter in the exhaust fan, can both helpful. Based on the VE technique used in this study, study results show that with a 420 thousand NT$ investment, a 1.08 million NT$ saving in the electricity bill is feasible. In this case, the benefit to cost ratio is 2.5 and the investment could be recovered in one year. M.T. Wang Hui-Ping Tserng 王明德 曾惠斌 2011 學位論文 ; thesis 109 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣大學 === 土木工程學研究所 === 99 === Central kitchen, snack street, and restaurant are high power demand facilities. With high power consumptions, global warming situation could be deteriorated. A kilowatt〈kW-hr〉saving would be equivalent a 0.636 kg CO2 emission reduction. From a corporate point of view, energy saving in these facilities can not only be beneficial to environment protection, but also good for energy cost reduction, and consequently, enhancing the competitiveness of the corporation. In order to maintain technical advantage and reduce operation costs, chain restaurants set up fresh central kitchen to control their food quality and transportation cost. Other than the frozen facility, electric power requirement of ventilation system is high, which can directly affect the operation costs of the kitchen. In this respect, value engineering (VE) technique can be used to analyze the operation of a fresh central kitchen. Under the budget constraint, energy efficiency, energy saving and environment protection issues can be considered in the analysis in order to reduction overall business costs.. A specific fresh central kitchen case is used in this study to demonstrate the procedure of a VE analysis for ventilation improvement project that can effectively reduce the operation cost of the facility. The investigating works involved include ventilation testing, current situation and engineering difficulty assessment. Study results suggest that using power electronics inverter with exhaust fan and additional devices could improve overall performance and enhance energy management flexibility. Past operation practice focused only on the exhaust air volume, and paid little attention to the amount and adequacy of intake air. Appropriateness of the equipment types is another important issue that is yet to be addressed. In order to enhance energy efficiency and reach the goal of flexible energy management for achieving energy saving and carbon reduction, adding supplementary components in energy management system and inverter in the exhaust fan, can both helpful. Based on the VE technique used in this study, study results show that with a 420 thousand NT$ investment, a 1.08 million NT$ saving in the electricity bill is feasible. In this case, the benefit to cost ratio is 2.5 and the investment could be recovered in one year.
author2 M.T. Wang
author_facet M.T. Wang
Yi-Kun Chen
陳一坤
author Yi-Kun Chen
陳一坤
spellingShingle Yi-Kun Chen
陳一坤
A study of applying value engineering to improve the energy management system of fresh central kitchen
author_sort Yi-Kun Chen
title A study of applying value engineering to improve the energy management system of fresh central kitchen
title_short A study of applying value engineering to improve the energy management system of fresh central kitchen
title_full A study of applying value engineering to improve the energy management system of fresh central kitchen
title_fullStr A study of applying value engineering to improve the energy management system of fresh central kitchen
title_full_unstemmed A study of applying value engineering to improve the energy management system of fresh central kitchen
title_sort study of applying value engineering to improve the energy management system of fresh central kitchen
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/21980708344015639846
work_keys_str_mv AT yikunchen astudyofapplyingvalueengineeringtoimprovetheenergymanagementsystemoffreshcentralkitchen
AT chényīkūn astudyofapplyingvalueengineeringtoimprovetheenergymanagementsystemoffreshcentralkitchen
AT yikunchen jiàzhígōngchéngyīngyòngyúshēngxiānchúfángnéngyuánguǎnlǐxìtǒngzhīgǎishànyánjiū
AT chényīkūn jiàzhígōngchéngyīngyòngyúshēngxiānchúfángnéngyuánguǎnlǐxìtǒngzhīgǎishànyánjiū
AT yikunchen studyofapplyingvalueengineeringtoimprovetheenergymanagementsystemoffreshcentralkitchen
AT chényīkūn studyofapplyingvalueengineeringtoimprovetheenergymanagementsystemoffreshcentralkitchen
_version_ 1718091020293373952