CORRECTIONS OF NOX CONCENTRATION AND TOTAL EMISSION RATE OF THREE NATURAL GAS TURBINES TIME-SHARING BY ONE CEMS SYSTEM

碩士 === 元智大學 === 化學工程與材料科學學系 === 96 === The validity and correction for nitrogen oxides (NOx) concentration obtained by time-sharing CEMs monitoring of three sets of gas turbines (GT) equipped in a local power plant was investigated. Various parameters that may influence combustion, such as combustio...