Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement
碩士 === 大葉大學 === 機電自動化研究所碩士班 === 94 === This paper exploits a bending-up cantilever caused by residual stress to manufacture a micro gas flow sensor. Micro sensors not only have a smaller physical size than their traditional counterparts, but also provide a greater measurement accuracy and a higher s...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2006
|
Online Access: | http://ndltd.ncl.edu.tw/handle/24560890219622203053 |
id |
ndltd-TW-094DYU00689008 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-094DYU006890082015-12-18T04:03:46Z http://ndltd.ncl.edu.tw/handle/24560890219622203053 Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement 應用於高氣體流速之微懸臂流量感測器 Yu-Hsiang Wang 王禹翔 碩士 大葉大學 機電自動化研究所碩士班 94 This paper exploits a bending-up cantilever caused by residual stress to manufacture a micro gas flow sensor. Micro sensors not only have a smaller physical size than their traditional counterparts, but also provide a greater measurement accuracy and a higher sensitivity. In this study, mems techniques are used to deposit a silicon nitride layer on a silicon wafer to create a piezoresistive structure. A platinum layer is deposited on the silicon nitride layer to form a resistor and the structure is then etched to form a freestanding micro-cantilever. It is found that the cantilever bends upward slightly as a result of the released residual stress induced in the beam during the fabrication process. When an airflow passes over the cantilever beam, a small deformation occurs. Variations in the airflow velocity can therefore be determined by measuring the change in resistance caused by the beam deflection using an LCR meter. e experimental data indicate that the proposed gas flow meter has a high sensitivity (0.0533 Ω/ms-1), a high measurement limit (44.47 ms-1) and a rapid response time. Chia-Yen Lee 李佳言 2006 學位論文 ; thesis 93 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 大葉大學 === 機電自動化研究所碩士班 === 94 === This paper exploits a bending-up cantilever caused by residual stress to manufacture a micro gas flow sensor. Micro sensors not only have a smaller physical size than their traditional counterparts, but also provide a greater measurement accuracy and a higher sensitivity. In this study, mems techniques are used to deposit a silicon nitride layer on a silicon wafer to create a piezoresistive structure. A platinum layer is deposited on the silicon nitride layer to form a resistor and the structure is then etched to form a freestanding micro-cantilever. It is found that the cantilever bends upward slightly as a result of the released residual stress induced in the beam during the fabrication process. When an airflow passes over the cantilever beam, a small deformation occurs. Variations in the airflow velocity can therefore be determined by measuring the change in resistance caused by the beam deflection using an LCR meter. e experimental data indicate that the proposed gas flow meter has a high sensitivity (0.0533 Ω/ms-1), a high measurement limit (44.47 ms-1) and a rapid response time.
|
author2 |
Chia-Yen Lee |
author_facet |
Chia-Yen Lee Yu-Hsiang Wang 王禹翔 |
author |
Yu-Hsiang Wang 王禹翔 |
spellingShingle |
Yu-Hsiang Wang 王禹翔 Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement |
author_sort |
Yu-Hsiang Wang |
title |
Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement |
title_short |
Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement |
title_full |
Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement |
title_fullStr |
Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement |
title_full_unstemmed |
Micro Cantilever-Based Flow Meter for High Airflow Velocity Measurement |
title_sort |
micro cantilever-based flow meter for high airflow velocity measurement |
publishDate |
2006 |
url |
http://ndltd.ncl.edu.tw/handle/24560890219622203053 |
work_keys_str_mv |
AT yuhsiangwang microcantileverbasedflowmeterforhighairflowvelocitymeasurement AT wángyǔxiáng microcantileverbasedflowmeterforhighairflowvelocitymeasurement AT yuhsiangwang yīngyòngyúgāoqìtǐliúsùzhīwēixuánbìliúliànggǎncèqì AT wángyǔxiáng yīngyòngyúgāoqìtǐliúsùzhīwēixuánbìliúliànggǎncèqì |
_version_ |
1718153151042813952 |