Design of Electronic Ballast with Piezoelectric Transformer for Cold Cathode Fluorescent Lamps
碩士 === 國立中山大學 === 電機工程學系研究所 === 90 === To minimize the size of the electronic ballast, a half-bridge load- resonant inverter with a cascading Rosen-type piezoelectric transformer (PT) is designed for cold cathode fluorescent lamps (CCFLs). The electrical characteristics of the PT are investigated...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2002
|
Online Access: | http://ndltd.ncl.edu.tw/handle/67685310780790952745 |