DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES

This thesis examines the development and testing of a novel 2 DOF (Degrees of Freedom) thermal actuator using Micro Electro Mechanical Systems (MEMS) technology. A out-of-plane displacement measurement technique based on optical focus adjustments is also implemented and tested. In-plane displacement...

Full description

Bibliographic Details
Main Author: d'Entremont, Rene
Language:en
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/10222/14021
id ndltd-LACETR-oai-collectionscanada.gc.ca-NSHD.ca#10222-14021
record_format oai_dc
spelling ndltd-LACETR-oai-collectionscanada.gc.ca-NSHD.ca#10222-140212013-10-04T04:12:51ZDEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUESd'Entremont, Rene2DOFmeasurement techniqueMEMSPolyMUMPSThermal actuatorThis thesis examines the development and testing of a novel 2 DOF (Degrees of Freedom) thermal actuator using Micro Electro Mechanical Systems (MEMS) technology. A out-of-plane displacement measurement technique based on optical focus adjustments is also implemented and tested. In-plane displacement measurement techniques are also compared. Existing MEMS actuator can either move in-plane or out-of-plane but no reported actuators were found to move in a user selectable combination of both domains. The novel actuator fabricated using the PolyMUMPs process is capable of displacements of 5 ?m out-of-plane and 1.5 ?m in-plane. A Finite Element Analysis (FEA) was performed as a proof of concept prior to physical construction. FEA was also used to characterize the actuator. Measuring out-of-plane displacements of MEMS devices is difficult to accomplish using only a standard microscope and camera setup. Methods have included tilting the chip so the vertical motion has a planar component. The most common commercial measurement technique uses interferomery but special expensive equipment is necessary. A method adapted from biological autofocus is proposed in which multiple images (100+) are taken at various focal planes. An algorithm is applied which extracts the most focused image. An out-of-plane displacement measurement can be extracted between two image sets. Results were compared to optical profiler measurements and the results had an average error of 0.47 ?m A comparison of planar displacement measurement methods, which included two variations of both edge detection and pattern matching along with measurements using the optical profiler, was accomplished. Consistent planar displacement results were collected for all techniques except for the simple edge detection.2011-08-12T13:41:16Z2011-08-12T13:41:16Z2011-08-122011-07-20http://hdl.handle.net/10222/14021en
collection NDLTD
language en
sources NDLTD
topic 2DOF
measurement technique
MEMS
PolyMUMPS
Thermal actuator
spellingShingle 2DOF
measurement technique
MEMS
PolyMUMPS
Thermal actuator
d'Entremont, Rene
DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES
description This thesis examines the development and testing of a novel 2 DOF (Degrees of Freedom) thermal actuator using Micro Electro Mechanical Systems (MEMS) technology. A out-of-plane displacement measurement technique based on optical focus adjustments is also implemented and tested. In-plane displacement measurement techniques are also compared. Existing MEMS actuator can either move in-plane or out-of-plane but no reported actuators were found to move in a user selectable combination of both domains. The novel actuator fabricated using the PolyMUMPs process is capable of displacements of 5 ?m out-of-plane and 1.5 ?m in-plane. A Finite Element Analysis (FEA) was performed as a proof of concept prior to physical construction. FEA was also used to characterize the actuator. Measuring out-of-plane displacements of MEMS devices is difficult to accomplish using only a standard microscope and camera setup. Methods have included tilting the chip so the vertical motion has a planar component. The most common commercial measurement technique uses interferomery but special expensive equipment is necessary. A method adapted from biological autofocus is proposed in which multiple images (100+) are taken at various focal planes. An algorithm is applied which extracts the most focused image. An out-of-plane displacement measurement can be extracted between two image sets. Results were compared to optical profiler measurements and the results had an average error of 0.47 ?m A comparison of planar displacement measurement methods, which included two variations of both edge detection and pattern matching along with measurements using the optical profiler, was accomplished. Consistent planar displacement results were collected for all techniques except for the simple edge detection.
author d'Entremont, Rene
author_facet d'Entremont, Rene
author_sort d'Entremont, Rene
title DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES
title_short DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES
title_full DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES
title_fullStr DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES
title_full_unstemmed DEVELOPMENT OF NOVEL 2 DOF THERMAL MICRO ACTUATORS AND A COMPARISON OF DIFFERENT DISPLACEMENT MEASUREMENT TECHNIQUES
title_sort development of novel 2 dof thermal micro actuators and a comparison of different displacement measurement techniques
publishDate 2011
url http://hdl.handle.net/10222/14021
work_keys_str_mv AT dentremontrene developmentofnovel2dofthermalmicroactuatorsandacomparisonofdifferentdisplacementmeasurementtechniques
_version_ 1716601303203840000