Experimental investigation on system performances and transient response of a pumped two-phase battery cooling system using R1233zd

This study presents an experimental investigation on the pumped two-phase cooling system designed for battery thermal management. The experimental system was established with R1233zd as the refrigerant, and a dummy battery was used to simulate the heat generation during battery operation. The thermo...