Experimental investigation on system performances and transient response of a pumped two-phase battery cooling system using R1233zd

This study presents an experimental investigation on the pumped two-phase cooling system designed for battery thermal management. The experimental system was established with R1233zd as the refrigerant, and a dummy battery was used to simulate the heat generation during battery operation. The thermo...

Full description

Bibliographic Details
Main Authors: Yidong Fang, Fei Ye, Yue Zhu, Kang Li, Jiali Shen, Lin Su
Format: Article
Language:English
Published: Elsevier 2020-12-01
Series:Energy Reports
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2352484720312439