Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts

4,4′-Methylene diphenyl diisocyanate (herein 4,4′-MDI) is used in the production of polyurethane foams, elastomers, coatings, adhesives and the like for a wide range of commercial products. Occupational exposure to MDI levels above current airborne exposure limits can elicit immune mediated hypersen...

Full description

Bibliographic Details
Main Authors: Leah G. Luna, Brett J. Green, Fagen Zhang, Scott M. Arnold, Paul D. Siegel, Michael J. Bartels
Format: Article
Language:English
Published: Elsevier 2014-01-01
Series:Toxicology Reports
Subjects:
MDI
Online Access:http://www.sciencedirect.com/science/article/pii/S2214750014000900
id doaj-f6a72aebae4f42ed8bbe3066fe5a7348
record_format Article
spelling doaj-f6a72aebae4f42ed8bbe3066fe5a73482020-11-25T00:25:23ZengElsevierToxicology Reports2214-75002014-01-011C74375110.1016/j.toxrep.2014.09.009Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adductsLeah G. Luna0Brett J. Green1Fagen Zhang2Scott M. Arnold3Paul D. Siegel4Michael J. Bartels5Toxicology, Environmental Research and Consulting, The Dow Chemical Company, United StatesAllergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, United StatesToxicology, Environmental Research and Consulting, The Dow Chemical Company, United StatesToxicology, Environmental Research and Consulting, The Dow Chemical Company, United StatesAllergy and Clinical Immunology Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, United StatesToxicology, Environmental Research and Consulting, The Dow Chemical Company, United States4,4′-Methylene diphenyl diisocyanate (herein 4,4′-MDI) is used in the production of polyurethane foams, elastomers, coatings, adhesives and the like for a wide range of commercial products. Occupational exposure to MDI levels above current airborne exposure limits can elicit immune mediated hypersensitivity reactions such as occupational asthma in sensitive individuals. To accurately determine exposure, there has been increasing interest in developing analytical methods to measure internal biomarkers of exposure to MDI. Previous investigators have reported methodologies for measuring MDI diamine metabolites and MDI-Lysine (4,4′-MDI-Lys) adducts. The purpose of this study was to develop and validate an ultra performance liquid chromatography isotope dilution tandem mass spectrometry (UPLC-ID/MS/MS) quantitation method via a signature peptide approach to enable biomonitoring of 4,4′-MDI adducted to human serum albumin (HSA) in plasma. A murine, anti-4,4′-MDI monoclonal IgM antibody was bound to magnetic beads and utilized for enrichment of the MDI adducted HSA. Following enrichment, trypsin digestion was performed to generate the expected 414 site (primary site of adduction) 4,4′-MDI-adducted HSA signature peptide that was quantified by UPLC-ID/MS/MS. An Agilent 6530 UPLC/quadrupole time of flight MS (QTOF) system was utilized for intact adducted protein analysis and an Agilent 6490 UPLC/MS/MS system operated in multiple reaction monitoring (MRM) mode was utilized for quantification of the adducted signature peptide biomarker both for in chemico and worker serum samples. Worker serum samples were initially screened utilizing the previously developed 4,4′-MDI-Lys amino acid method and results showed that 12 samples were identified as quantifiable for 4,4′-MDI-Lys adducts. The signature peptide adduct approach was applied to the 12 worker samples identified as quantifiable for 4,4′-MDI-Lys adducts. Results indicated no positive results were obtained above the quantification limit by the signature peptide approach. If the 414 site of lysine adduction accounted for 100% of the 4,4′-MDI adductions in the signature peptide adduct approach, the three highest quantifiable samples by the 4,4′-MDI-Lys method should have at least been detectable by the signature peptide method. Results show that although the 4,4′-MDI signature peptide approach is more selective, it is 18 times less sensitive than the 4,4′-MDI-Lys method, thus limiting the ability to detect adduct levels relative to the 4,4′-MDI-Lys amino acid method.http://www.sciencedirect.com/science/article/pii/S2214750014000900MDIAdductMass spectrometryDiisocyanatesBiomarkers
collection DOAJ
language English
format Article
sources DOAJ
author Leah G. Luna
Brett J. Green
Fagen Zhang
Scott M. Arnold
Paul D. Siegel
Michael J. Bartels
spellingShingle Leah G. Luna
Brett J. Green
Fagen Zhang
Scott M. Arnold
Paul D. Siegel
Michael J. Bartels
Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
Toxicology Reports
MDI
Adduct
Mass spectrometry
Diisocyanates
Biomarkers
author_facet Leah G. Luna
Brett J. Green
Fagen Zhang
Scott M. Arnold
Paul D. Siegel
Michael J. Bartels
author_sort Leah G. Luna
title Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
title_short Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
title_full Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
title_fullStr Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
title_full_unstemmed Quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
title_sort quantitation of 4,4′-methylene diphenyl diisocyanate human serum albumin adducts
publisher Elsevier
series Toxicology Reports
issn 2214-7500
publishDate 2014-01-01
description 4,4′-Methylene diphenyl diisocyanate (herein 4,4′-MDI) is used in the production of polyurethane foams, elastomers, coatings, adhesives and the like for a wide range of commercial products. Occupational exposure to MDI levels above current airborne exposure limits can elicit immune mediated hypersensitivity reactions such as occupational asthma in sensitive individuals. To accurately determine exposure, there has been increasing interest in developing analytical methods to measure internal biomarkers of exposure to MDI. Previous investigators have reported methodologies for measuring MDI diamine metabolites and MDI-Lysine (4,4′-MDI-Lys) adducts. The purpose of this study was to develop and validate an ultra performance liquid chromatography isotope dilution tandem mass spectrometry (UPLC-ID/MS/MS) quantitation method via a signature peptide approach to enable biomonitoring of 4,4′-MDI adducted to human serum albumin (HSA) in plasma. A murine, anti-4,4′-MDI monoclonal IgM antibody was bound to magnetic beads and utilized for enrichment of the MDI adducted HSA. Following enrichment, trypsin digestion was performed to generate the expected 414 site (primary site of adduction) 4,4′-MDI-adducted HSA signature peptide that was quantified by UPLC-ID/MS/MS. An Agilent 6530 UPLC/quadrupole time of flight MS (QTOF) system was utilized for intact adducted protein analysis and an Agilent 6490 UPLC/MS/MS system operated in multiple reaction monitoring (MRM) mode was utilized for quantification of the adducted signature peptide biomarker both for in chemico and worker serum samples. Worker serum samples were initially screened utilizing the previously developed 4,4′-MDI-Lys amino acid method and results showed that 12 samples were identified as quantifiable for 4,4′-MDI-Lys adducts. The signature peptide adduct approach was applied to the 12 worker samples identified as quantifiable for 4,4′-MDI-Lys adducts. Results indicated no positive results were obtained above the quantification limit by the signature peptide approach. If the 414 site of lysine adduction accounted for 100% of the 4,4′-MDI adductions in the signature peptide adduct approach, the three highest quantifiable samples by the 4,4′-MDI-Lys method should have at least been detectable by the signature peptide method. Results show that although the 4,4′-MDI signature peptide approach is more selective, it is 18 times less sensitive than the 4,4′-MDI-Lys method, thus limiting the ability to detect adduct levels relative to the 4,4′-MDI-Lys amino acid method.
topic MDI
Adduct
Mass spectrometry
Diisocyanates
Biomarkers
url http://www.sciencedirect.com/science/article/pii/S2214750014000900
work_keys_str_mv AT leahgluna quantitationof44methylenediphenyldiisocyanatehumanserumalbuminadducts
AT brettjgreen quantitationof44methylenediphenyldiisocyanatehumanserumalbuminadducts
AT fagenzhang quantitationof44methylenediphenyldiisocyanatehumanserumalbuminadducts
AT scottmarnold quantitationof44methylenediphenyldiisocyanatehumanserumalbuminadducts
AT pauldsiegel quantitationof44methylenediphenyldiisocyanatehumanserumalbuminadducts
AT michaeljbartels quantitationof44methylenediphenyldiisocyanatehumanserumalbuminadducts
_version_ 1725349312911638528