Research of Small Sheet-Type Laminar Flow Meter

A small sheet-type LFM is proposed to solve the problems of leakage and deformation in the design of traditional sheet-type LFM. The pressure tap is set in the middle of the laminar flow channel to extract pressure from the fully developed laminar flow. The design value Remax·de/l is 5.81, which is...

Full description

Bibliographic Details
Format: Article
Language:zho
Published: The Northwestern Polytechnical University 2020-08-01
Series:Xibei Gongye Daxue Xuebao
Subjects:
Online Access:https://www.jnwpu.org/articles/jnwpu/full_html/2020/04/jnwpu2020384p792/jnwpu2020384p792.html
id doaj-f39703fe48c44860bcedce314a129f6c
record_format Article
spelling doaj-f39703fe48c44860bcedce314a129f6c2021-05-03T01:48:25ZzhoThe Northwestern Polytechnical UniversityXibei Gongye Daxue Xuebao1000-27582609-71252020-08-0138479279610.1051/jnwpu/20203840792jnwpu2020384p792Research of Small Sheet-Type Laminar Flow Meter0123School of Power and Energy, Northwestern Polytechnical UniversitySchool of Power and Energy, Northwestern Polytechnical UniversitySchool of Power and Energy, Northwestern Polytechnical UniversitySchool of Power and Energy, Northwestern Polytechnical UniversityA small sheet-type LFM is proposed to solve the problems of leakage and deformation in the design of traditional sheet-type LFM. The pressure tap is set in the middle of the laminar flow channel to extract pressure from the fully developed laminar flow. The design value Remax·de/l is 5.81, which is much higher than the 2~2.5 required by the traditional design. Experimental results show that the linearity factor ξL of small sheet-type LFM can reach 0.81% and the accuracy is up to 1%, which shows that the present design can effectively overcome the nonlinear effects caused by sudden expansion and contraction. In addition, when the flow rate is above 20% designed maximum valve, the calculation error of pressure drop can be controlled below 5.42%.https://www.jnwpu.org/articles/jnwpu/full_html/2020/04/jnwpu2020384p792/jnwpu2020384p792.htmllaminar flow metersheet-typesudden expansion and contractionlinearityaccuracy
collection DOAJ
language zho
format Article
sources DOAJ
title Research of Small Sheet-Type Laminar Flow Meter
spellingShingle Research of Small Sheet-Type Laminar Flow Meter
Xibei Gongye Daxue Xuebao
laminar flow meter
sheet-type
sudden expansion and contraction
linearity
accuracy
title_short Research of Small Sheet-Type Laminar Flow Meter
title_full Research of Small Sheet-Type Laminar Flow Meter
title_fullStr Research of Small Sheet-Type Laminar Flow Meter
title_full_unstemmed Research of Small Sheet-Type Laminar Flow Meter
title_sort research of small sheet-type laminar flow meter
publisher The Northwestern Polytechnical University
series Xibei Gongye Daxue Xuebao
issn 1000-2758
2609-7125
publishDate 2020-08-01
description A small sheet-type LFM is proposed to solve the problems of leakage and deformation in the design of traditional sheet-type LFM. The pressure tap is set in the middle of the laminar flow channel to extract pressure from the fully developed laminar flow. The design value Remax·de/l is 5.81, which is much higher than the 2~2.5 required by the traditional design. Experimental results show that the linearity factor ξL of small sheet-type LFM can reach 0.81% and the accuracy is up to 1%, which shows that the present design can effectively overcome the nonlinear effects caused by sudden expansion and contraction. In addition, when the flow rate is above 20% designed maximum valve, the calculation error of pressure drop can be controlled below 5.42%.
topic laminar flow meter
sheet-type
sudden expansion and contraction
linearity
accuracy
url https://www.jnwpu.org/articles/jnwpu/full_html/2020/04/jnwpu2020384p792/jnwpu2020384p792.html
_version_ 1721485527251681280