Research of Small Sheet-Type Laminar Flow Meter

A small sheet-type LFM is proposed to solve the problems of leakage and deformation in the design of traditional sheet-type LFM. The pressure tap is set in the middle of the laminar flow channel to extract pressure from the fully developed laminar flow. The design value Remax·de/l is 5.81, which is...