Fast testing of ambient temperature pitting corrosion in type 2205 duplex stainless steel by bipolar electrochemistry experiments
Commercial grade type 2205 duplex stainless steel is resistant to localised corrosion at room temperature. With the application of bipolar electrochemistry, pitting and crevice corrosion can be probed at room temperature, with corrosion pits nucleated in 0.1 M HCl within 15 s of exposure. The evolut...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2020-08-01
|
Series: | Electrochemistry Communications |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S1388248120301302 |