Time change of steel and coating film applied to the old living hut built in 1969 at Syowa Station, Antarctica
The results of an investigation of steel and paint coated galvanized steel sheet used in the old living hut built in 1969 at Syowa Station, Antarctica are described. The steel corrosion products consist of α-FeOOH and γ-FeOOH, which are produced in air, and the mineral component CaAl2SiO8. However,...