Investigations into packaging technology for membrane-based thermal flow sensors

A new packaging method to mount a membrane-based thermal flow sensor, flush with the surface, is presented. Therefore, a specific design for the housing is shown, which is also adaptable to other conditions. It has been experimentally shown that it is important to mount the sensor flush with the sur...

Full description

Bibliographic Details
Main Authors: G. Dumstorff, E. Brauns, W. Lang
Format: Article
Language:English
Published: Copernicus Publications 2015-02-01
Series:Journal of Sensors and Sensor Systems
Online Access:http://www.j-sens-sens-syst.net/4/45/2015/jsss-4-45-2015.pdf
Description
Summary:A new packaging method to mount a membrane-based thermal flow sensor, flush with the surface, is presented. Therefore, a specific design for the housing is shown, which is also adaptable to other conditions. It has been experimentally shown that it is important to mount the sensor flush with the surface. In addition, the experimental results are discussed. If a membrane-based thermal flow sensor is not mounted flush with the surface, vortices can occur (depending on velocity and fluid properties) or the reduction in the channel cross section plus a decrease in sensitivity have to be taken into account.