Comparison of steam technology and a two-step cleaning (water/detergent) and disinfecting (1,000 resp. 5,000 ppm hypochlorite) method using microfiber cloth for environmental control of multidrug-resistant organisms in an intensive care unit

Aim: The aim of this prospective observational study was to evaluate the impact of two cleaning and disinfecting methods and the use of steam against methicillin-resistant , vancomycin-resistant , carbapenem-resistant and multidrug-resistant (MDR) in a tertiary referral hospital. Methods: McFarlan...

Full description

Bibliographic Details
Main Authors: Oztoprak, Nefise, Kizilates, Filiz, Percin, Duygu
Format: Article
Language:deu
Published: German Medical Science GMS Publishing House 2019-10-01
Series:GMS Hygiene and Infection Control
Subjects:
Online Access:http://www.egms.de/static/en/journals/dgkh/2019-14/dgkh000330.shtml