Analysis and Design of a Delta-Type Interior Permanent Magnet Synchronous Generator by Using an Analytic Method
The analytic analysis of delta-type interior permanent synchronous machines is difficult due to the absence of a useful analytic method, especially considering the high magnetic saturation effect of the machine. Hence, the nonlinear magnetic equivalent circuit (MEC) method, which considers the sever...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
IEEE
2019-01-01
|
Series: | IEEE Access |
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8744197/ |