High heat flux testing of first wall mock-ups with and without neutron irradiation

Beryllium as the plasma facing material for the first wall of ITER will be exposed to thermal, particle and neutron loads. In the frame of the European qualification program for ITER, two HIPped beryllium small scale flat-tile mock-ups consisting of a steel support structure, a CuCrZr/Cu heat sink a...

Full description

Bibliographic Details
Main Authors: G. Pintsuk, B. Bellin, A. Gervash, J. Linke, N. Litunovsky, P. Lorenzetto
Format: Article
Language:English
Published: Elsevier 2016-12-01
Series:Nuclear Materials and Energy
Subjects: