Corrosion of titanium alloys in pressurized water at 300 °C and 15 MPa

Commercially pure titanium (Ti CP) and two titanium alloys (Ti 64 and Ti10-2-3) representative of different metallurgical classes were exposed to pressurized water at 300 °C, 15 MPa in a dedicated stainless steel corrosion loop up to 1632 h. Mass uptake measurements as well as extensive characteriza...

Full description

Bibliographic Details
Main Authors: Quentin BIGNON, Quentin AUZOUX, Frantz MARTIN, Amandine RAYNAL, Frédéric MISERQUE, Michel TABARANT, Laurence LATU-ROMAIN, Yves WOUTERS
Format: Article
Language:English
Published: EDP Sciences 2020-01-01
Series:MATEC Web of Conferences
Online Access:https://www.matec-conferences.org/articles/matecconf/pdf/2020/17/matecconf_ti2019_06006.pdf