Systematic comparison of four point-of-care methods versus the reference laboratory measurement of hemoglobin in the surgical ICU setting: a cross-sectional method comparison study

Abstract Background Transfusion decision during the perioperative period mostly relies on the point-of-care testing for Hb measurement. This study aimed systematically compared four point-of-care methods with the central laboratory measurement of hemoglobin (LHb) regarding the accuracy, precision, a...

Full description

Bibliographic Details
Main Authors: Arpa Chutipongtanate, Churairat Yasaeng, Tanit Virankabutra, Somchai Chutipongtanate
Format: Article
Language:English
Published: BMC 2020-04-01
Series:BMC Anesthesiology
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12871-020-01008-8