Effects of oil channels and oil flow rate on cooling performance of closed circuit axial piston transmission
Closed circuit axial piston transmission (CCAPT) has been implemented in the field of hydraulic transmission. As a result of frictional loss and leakage loss, the temperature rise is unavoidable, that can shorten the service life of crucial components. Based on the method of computational fluid dyna...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2021-12-01
|
Series: | Case Studies in Thermal Engineering |
Subjects: | |
Online Access: | http://www.sciencedirect.com/science/article/pii/S2214157X21005384 |