Diagnosis of Static Eccentricity in 3-Phase Synchronous Machines using a Pseudo Zero-Sequence Current
Large synchronous generators are the heart of the modern world, while producing the vast majority of the electric power consumed globally. Although they are robust devices, they are prone to degradation and failure. If such failures are not detected at an early stage, then the negative impact may be...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI AG
2019-06-01
|
Series: | Energies |
Subjects: | |
Online Access: | https://www.mdpi.com/1996-1073/12/13/2476 |