Detection of Static Eccentricity Fault in Saturated Induction Motors by Air-Gap Magnetic Flux Signature Analysis Using Finite Element Method

Unfortunately, motor current signature analysis (MCSA) cannot detect the small degrees of the purely static eccentricity (SE) defects, while the air-gap magnetic flux signature analysis (FSA) is applied successfully. The simulation results are obtained by using time stepping finite elements (TSFE) m...

Full description

Bibliographic Details
Main Authors: N. Halem, S. E. Zouzou, K. Srairi, S. Guedidi, F. A. Abood
Format: Article
Language:English
Published: El Oued University 2013-06-01
Series:Journal of Fundamental and Applied Sciences
Subjects:
Online Access:http://www.jfas.info/index.php/JFAS/article/view/152/pdf