Thermal damage width and hemostatic effect of bipolar electrocoagulation, LigaSure, and Ultracision techniques on goat mesenteric vessels and optimal power for bipolar electrocoagulation
Abstract Background We aimed to determine the optimal bipolar electrocoagulation power for laparoscopic surgery and to investigate which method, bipolar electrocoagulation, advanced bipolar, or ultrasonic technique was more reliable. Methods Goat mesenteric vessels (210 in vivo samples) with diamete...