Influence of Bimoment Restraints on the Load-Bearing Capacity of a Steel I-Beam

The study presents an analysis of steel I-beam warping. The calculations were made for hot-rolled IPE200 hinged beams with different lengths. After determining load-bearing capacity using the GMNIA method, the beams were strengthened with bimoment restraints at each end. The changes in critical mome...

Full description

Bibliographic Details
Main Author: Wierzbicki Krzysztof
Format: Article
Language:English
Published: Sciendo 2020-12-01
Series:Civil and Environmental Engineering Reports
Subjects:
Online Access:https://doi.org/10.2478/ceer-2020-0048