Simple and Robust Analysis of Cefuroxime in Human Plasma by LC-MS/MS: Application to a Bioequivalence Study

A simple, robust LC-MS/MS assay for quantifying cefuroxime in human plasma was developed. Cefuroxime and tazobactam, as internal standard (IS), were extracted from human plasma by methanol to precipitate protein. Separation was achieved on a Zorbax SB-Aq (4.6×250 mm, 5 μm) column under isocratic con...

Full description

Bibliographic Details
Main Authors: Xingjiang Hu, Mingzhu Huang, Jian Liu, Junchun Chen, Jianzhong Shentu
Format: Article
Language:English
Published: Hindawi Limited 2014-01-01
Series:Advances in Pharmacological Sciences