Square-edge intraocular lens versus conventional round-edge intraocular lens in prevention of posterior capsule opacification: A randomized clinical trial

Aim: To determine whether square-edge polymethyl methacrylate (PMMA) intraocular lens (IOL) is superior in preventing clinically significant posterior capsule opacification (PCO) and better visual outcome when compared with round-edge PMMA IOL in manual small-incision cataract surgery (MSICS). Setti...

Full description

Bibliographic Details
Main Authors: Rekha R Mudhol, Samyakta A Shetti, Deepaka Kumar Dodamani
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Journal of the Scientific Society
Subjects:
Online Access:http://www.jscisociety.com/article.asp?issn=0974-5009;year=2016;volume=43;issue=1;spage=6;epage=10;aulast=Mudhol