Detection and classification of turn fault and high-resistance connection fault in inverter-fed permanent magnet machines based on high-frequency signals
Winding turn fault and high-resistance connection (HRC) fault will lead to different consequences and require different mitigation actions. In this study, the differentiating features between a turn fault and HRC fault are analysed and compared in a three-phase surface-mounted permanent magnet machi...