RIBBED DOUBLE PIPE HEAT EXCHANGER: ANALYTICAL ANALYSIS
This paper presents the findings obtained by modeling a Double Pipe Heat Exchanger (DPHE) equipped with repeated ribs from the inside for artificial roughing. An analytical procedure was developed to analyze the thermal and hydraulic performance of the DPHE with and without ribbing. The procedure wa...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Taylor's University
2011-02-01
|
Series: | Journal of Engineering Science and Technology |
Subjects: | |
Online Access: | http://jestec.taylors.edu.my/Vol%206%20Issue%201%20February%2011/Vol_6_1__039_049_HUSSAIN%20H.pdf |