Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns

A new GC/MS method for the determination of diacetyl and 2,3-pentanedione was investigated. Diacetyl and 2,3-pentanedione were derivatized with 1,2-diaminobenzene to form 2,3-dimetylquinoxaline and 2-ethyl-3-methylquinoxaline. respectively. The amounts of formed 2.3-dimetylqu:inoxaline and 2-ethyl-3...

Full description

Bibliographic Details
Main Authors: Pejin Jelena D., Grujić Olgica S., Marjanović Nikola J., Vujić Đura N., Kocić-Tanackov Sunčica D.
Format: Article
Language:English
Published: Faculty of Technology, Novi Sad 2002-01-01
Series:Acta Periodica Technologica
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/1450-7188/2002/1450-71880233045P.pdf
id doaj-7840033deb3b4b38910043994e98f8c9
record_format Article
spelling doaj-7840033deb3b4b38910043994e98f8c92020-11-24T23:38:30ZengFaculty of Technology, Novi SadActa Periodica Technologica1450-71882002-01-01200233455410.2298/APT0233045PDetermina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columnsPejin Jelena D.Grujić Olgica S.Marjanović Nikola J.Vujić Đura N.Kocić-Tanackov Sunčica D.A new GC/MS method for the determination of diacetyl and 2,3-pentanedione was investigated. Diacetyl and 2,3-pentanedione were derivatized with 1,2-diaminobenzene to form 2,3-dimetylquinoxaline and 2-ethyl-3-methylquinoxaline. respectively. The amounts of formed 2.3-dimetylqu:inoxaline and 2-ethyl-3,.methylquinoxaline were proportional to the concentrations of diacetyl and 2,3-penianedione present in the sample. 2,3-Dimetylquinoxaline and 2-ethyl-3-methylquinoxaline were extracted by solid-phase extraction (SPE) columns and determined by gas chromatography using a mass selective detector. This method was applied for the determination of diacetyl and 2,3-pentanedione concentrations in beer. Extraction by SPE columns proved to be very simple and reliable. The method can be used for simultaneous determination of diacetyl and 2,3-pentanedione concentrations in beer in a great number of beer samples. http://www.doiserbia.nb.rs/img/doi/1450-7188/2002/1450-71880233045P.pdfvicinal diketonesgas chromatographymass selective detectorbeer
collection DOAJ
language English
format Article
sources DOAJ
author Pejin Jelena D.
Grujić Olgica S.
Marjanović Nikola J.
Vujić Đura N.
Kocić-Tanackov Sunčica D.
spellingShingle Pejin Jelena D.
Grujić Olgica S.
Marjanović Nikola J.
Vujić Đura N.
Kocić-Tanackov Sunčica D.
Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
Acta Periodica Technologica
vicinal diketones
gas chromatography
mass selective detector
beer
author_facet Pejin Jelena D.
Grujić Olgica S.
Marjanović Nikola J.
Vujić Đura N.
Kocić-Tanackov Sunčica D.
author_sort Pejin Jelena D.
title Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
title_short Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
title_full Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
title_fullStr Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
title_full_unstemmed Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
title_sort determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
publisher Faculty of Technology, Novi Sad
series Acta Periodica Technologica
issn 1450-7188
publishDate 2002-01-01
description A new GC/MS method for the determination of diacetyl and 2,3-pentanedione was investigated. Diacetyl and 2,3-pentanedione were derivatized with 1,2-diaminobenzene to form 2,3-dimetylquinoxaline and 2-ethyl-3-methylquinoxaline. respectively. The amounts of formed 2.3-dimetylqu:inoxaline and 2-ethyl-3,.methylquinoxaline were proportional to the concentrations of diacetyl and 2,3-penianedione present in the sample. 2,3-Dimetylquinoxaline and 2-ethyl-3-methylquinoxaline were extracted by solid-phase extraction (SPE) columns and determined by gas chromatography using a mass selective detector. This method was applied for the determination of diacetyl and 2,3-pentanedione concentrations in beer. Extraction by SPE columns proved to be very simple and reliable. The method can be used for simultaneous determination of diacetyl and 2,3-pentanedione concentrations in beer in a great number of beer samples.
topic vicinal diketones
gas chromatography
mass selective detector
beer
url http://www.doiserbia.nb.rs/img/doi/1450-7188/2002/1450-71880233045P.pdf
work_keys_str_mv AT pejinjelenad determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns
AT grujicolgicas determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns
AT marjanovicnikolaj determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns
AT vujicđuran determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns
AT kocictanackovsuncicad determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns
_version_ 1725516783237988352