Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns
A new GC/MS method for the determination of diacetyl and 2,3-pentanedione was investigated. Diacetyl and 2,3-pentanedione were derivatized with 1,2-diaminobenzene to form 2,3-dimetylquinoxaline and 2-ethyl-3-methylquinoxaline. respectively. The amounts of formed 2.3-dimetylqu:inoxaline and 2-ethyl-3...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Technology, Novi Sad
2002-01-01
|
Series: | Acta Periodica Technologica |
Subjects: | |
Online Access: | http://www.doiserbia.nb.rs/img/doi/1450-7188/2002/1450-71880233045P.pdf |
id |
doaj-7840033deb3b4b38910043994e98f8c9 |
---|---|
record_format |
Article |
spelling |
doaj-7840033deb3b4b38910043994e98f8c92020-11-24T23:38:30ZengFaculty of Technology, Novi SadActa Periodica Technologica1450-71882002-01-01200233455410.2298/APT0233045PDetermina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columnsPejin Jelena D.Grujić Olgica S.Marjanović Nikola J.Vujić Đura N.Kocić-Tanackov Sunčica D.A new GC/MS method for the determination of diacetyl and 2,3-pentanedione was investigated. Diacetyl and 2,3-pentanedione were derivatized with 1,2-diaminobenzene to form 2,3-dimetylquinoxaline and 2-ethyl-3-methylquinoxaline. respectively. The amounts of formed 2.3-dimetylqu:inoxaline and 2-ethyl-3,.methylquinoxaline were proportional to the concentrations of diacetyl and 2,3-penianedione present in the sample. 2,3-Dimetylquinoxaline and 2-ethyl-3-methylquinoxaline were extracted by solid-phase extraction (SPE) columns and determined by gas chromatography using a mass selective detector. This method was applied for the determination of diacetyl and 2,3-pentanedione concentrations in beer. Extraction by SPE columns proved to be very simple and reliable. The method can be used for simultaneous determination of diacetyl and 2,3-pentanedione concentrations in beer in a great number of beer samples. http://www.doiserbia.nb.rs/img/doi/1450-7188/2002/1450-71880233045P.pdfvicinal diketonesgas chromatographymass selective detectorbeer |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Pejin Jelena D. Grujić Olgica S. Marjanović Nikola J. Vujić Đura N. Kocić-Tanackov Sunčica D. |
spellingShingle |
Pejin Jelena D. Grujić Olgica S. Marjanović Nikola J. Vujić Đura N. Kocić-Tanackov Sunčica D. Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns Acta Periodica Technologica vicinal diketones gas chromatography mass selective detector beer |
author_facet |
Pejin Jelena D. Grujić Olgica S. Marjanović Nikola J. Vujić Đura N. Kocić-Tanackov Sunčica D. |
author_sort |
Pejin Jelena D. |
title |
Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns |
title_short |
Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns |
title_full |
Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns |
title_fullStr |
Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns |
title_full_unstemmed |
Determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns |
title_sort |
determina tion of diacetyl and 2,3-pentanedione in beer by gc/ms using solid-phase extraction columns |
publisher |
Faculty of Technology, Novi Sad |
series |
Acta Periodica Technologica |
issn |
1450-7188 |
publishDate |
2002-01-01 |
description |
A new GC/MS method for the determination of diacetyl and 2,3-pentanedione was investigated. Diacetyl and 2,3-pentanedione were derivatized with 1,2-diaminobenzene to form 2,3-dimetylquinoxaline and 2-ethyl-3-methylquinoxaline. respectively. The amounts of formed 2.3-dimetylqu:inoxaline and 2-ethyl-3,.methylquinoxaline were proportional to the concentrations of diacetyl and 2,3-penianedione present in the sample. 2,3-Dimetylquinoxaline and 2-ethyl-3-methylquinoxaline were extracted by solid-phase extraction (SPE) columns and determined by gas chromatography using a mass selective detector. This method was applied for the determination of diacetyl and 2,3-pentanedione concentrations in beer. Extraction by SPE columns proved to be very simple and reliable. The method can be used for simultaneous determination of diacetyl and 2,3-pentanedione concentrations in beer in a great number of beer samples. |
topic |
vicinal diketones gas chromatography mass selective detector beer |
url |
http://www.doiserbia.nb.rs/img/doi/1450-7188/2002/1450-71880233045P.pdf |
work_keys_str_mv |
AT pejinjelenad determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns AT grujicolgicas determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns AT marjanovicnikolaj determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns AT vujicđuran determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns AT kocictanackovsuncicad determinationofdiacetyland23pentanedioneinbeerbygcmsusingsolidphaseextractioncolumns |
_version_ |
1725516783237988352 |