Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing

Abstract Background Reporter methods to quantitatively measure the efficiency and specificity of genome editing tools are important for the development of novel editing techniques and successful applications of available ones. However, the existing methods have major limitations in sensitivity, accu...

Full description

Bibliographic Details
Main Authors: Akhilesh Kumar, Michael D. Birnbaum, Balaji T. Moorthy, Jayanti Singh, Anna Palovcak, Devang M. Patel, Fangliang Zhang
Format: Article
Language:English
Published: BMC 2019-07-01
Series:BMC Genomics
Subjects:
Online Access:http://link.springer.com/article/10.1186/s12864-019-5963-z
id doaj-7749720163a84496b055d158d19e17a3
record_format Article
spelling doaj-7749720163a84496b055d158d19e17a32020-11-25T03:47:10ZengBMCBMC Genomics1471-21642019-07-0120111010.1186/s12864-019-5963-zInsertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editingAkhilesh Kumar0Michael D. Birnbaum1Balaji T. Moorthy2Jayanti Singh3Anna Palovcak4Devang M. Patel5Fangliang Zhang6Department of Molecular and Cellular Pharmacology, University of Miami, Miller School of MedicineDepartment of Molecular and Cellular Pharmacology, University of Miami, Miller School of MedicineDepartment of Molecular and Cellular Pharmacology, University of Miami, Miller School of MedicineDepartment of Otolaryngology, University of Miami, Miller School of MedicineDepartment of Biochemistry and Molecular Biology, University of Miami, Miller School of MedicineDepartment of Molecular and Cellular Pharmacology, University of Miami, Miller School of MedicineDepartment of Molecular and Cellular Pharmacology, University of Miami, Miller School of MedicineAbstract Background Reporter methods to quantitatively measure the efficiency and specificity of genome editing tools are important for the development of novel editing techniques and successful applications of available ones. However, the existing methods have major limitations in sensitivity, accuracy, and/or readiness for in vivo applications. Here, we aim to develop a straight-forward method by using nucleotide insertion/deletion resulted from genome editing. In this system, a target sequence with frame-shifting length is inserted after the start codon of a cerulean fluorescence protein (CFP) to inactivate its fluorescence. As such, only a new insertion/deletion event in the target sequence will reactivate the fluorescence. This reporter is therefore termed as “Insertion/deletion-activated frame-shift fluorescence protein”. To increase its traceability, an internal ribosome entry site and a red fluorescence protein mCherryFP are placed downstream of the reporter. The percentage of CFP-positive cells can be quantified by fluorescence measuring devices such as flow cytometer as the readout for genome editing frequency. Results To test the background noise level, sensitivity, and quantitative capacity of this new reporter, we applied this approach to examine the efficiency of genome editing of CRISPR/Cas9 on two different targeting sequences and in three different cell lines, in the presence or absence of guide-RNAs with or without efficiency-compromising mutations. We found that the insertion/deletion-activated frame-shift fluorescence protein has very low background signal, can detect low-efficiency genome editing events driven by mutated guideRNAs, and can quantitatively distinguish genome editing by normal or mutated guideRNA. To further test whether the positive editing event detected by this reporter indeed correspond to genuine insertion/deletion on the genome, we enriched the CFP-positive cells to examine their fluorescence under confocal microscope and to analyze the DNA sequence of the reporter in the genome by Sanger sequencing. We found that the positive events captured by this reporter indeed correlates with genuine DNA insertion/deletion in the expected genome location. Conclusion The insertion/deletion-activated frame-shift fluorescence protein reporter has very low background, high sensitivity, and is quantitative in nature. It will be able to facilitate the development of new genome editing tools as well as the application of existing tools.http://link.springer.com/article/10.1186/s12864-019-5963-zInsertion-deletionIn-delReporterCRIPSR-Cas9Genome editingNHEJ
collection DOAJ
language English
format Article
sources DOAJ
author Akhilesh Kumar
Michael D. Birnbaum
Balaji T. Moorthy
Jayanti Singh
Anna Palovcak
Devang M. Patel
Fangliang Zhang
spellingShingle Akhilesh Kumar
Michael D. Birnbaum
Balaji T. Moorthy
Jayanti Singh
Anna Palovcak
Devang M. Patel
Fangliang Zhang
Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing
BMC Genomics
Insertion-deletion
In-del
Reporter
CRIPSR-Cas9
Genome editing
NHEJ
author_facet Akhilesh Kumar
Michael D. Birnbaum
Balaji T. Moorthy
Jayanti Singh
Anna Palovcak
Devang M. Patel
Fangliang Zhang
author_sort Akhilesh Kumar
title Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing
title_short Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing
title_full Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing
title_fullStr Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing
title_full_unstemmed Insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic DNA editing
title_sort insertion/deletion-activated frame-shift fluorescence protein is a sensitive reporter for genomic dna editing
publisher BMC
series BMC Genomics
issn 1471-2164
publishDate 2019-07-01
description Abstract Background Reporter methods to quantitatively measure the efficiency and specificity of genome editing tools are important for the development of novel editing techniques and successful applications of available ones. However, the existing methods have major limitations in sensitivity, accuracy, and/or readiness for in vivo applications. Here, we aim to develop a straight-forward method by using nucleotide insertion/deletion resulted from genome editing. In this system, a target sequence with frame-shifting length is inserted after the start codon of a cerulean fluorescence protein (CFP) to inactivate its fluorescence. As such, only a new insertion/deletion event in the target sequence will reactivate the fluorescence. This reporter is therefore termed as “Insertion/deletion-activated frame-shift fluorescence protein”. To increase its traceability, an internal ribosome entry site and a red fluorescence protein mCherryFP are placed downstream of the reporter. The percentage of CFP-positive cells can be quantified by fluorescence measuring devices such as flow cytometer as the readout for genome editing frequency. Results To test the background noise level, sensitivity, and quantitative capacity of this new reporter, we applied this approach to examine the efficiency of genome editing of CRISPR/Cas9 on two different targeting sequences and in three different cell lines, in the presence or absence of guide-RNAs with or without efficiency-compromising mutations. We found that the insertion/deletion-activated frame-shift fluorescence protein has very low background signal, can detect low-efficiency genome editing events driven by mutated guideRNAs, and can quantitatively distinguish genome editing by normal or mutated guideRNA. To further test whether the positive editing event detected by this reporter indeed correspond to genuine insertion/deletion on the genome, we enriched the CFP-positive cells to examine their fluorescence under confocal microscope and to analyze the DNA sequence of the reporter in the genome by Sanger sequencing. We found that the positive events captured by this reporter indeed correlates with genuine DNA insertion/deletion in the expected genome location. Conclusion The insertion/deletion-activated frame-shift fluorescence protein reporter has very low background, high sensitivity, and is quantitative in nature. It will be able to facilitate the development of new genome editing tools as well as the application of existing tools.
topic Insertion-deletion
In-del
Reporter
CRIPSR-Cas9
Genome editing
NHEJ
url http://link.springer.com/article/10.1186/s12864-019-5963-z
work_keys_str_mv AT akhileshkumar insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
AT michaeldbirnbaum insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
AT balajitmoorthy insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
AT jayantisingh insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
AT annapalovcak insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
AT devangmpatel insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
AT fangliangzhang insertiondeletionactivatedframeshiftfluorescenceproteinisasensitivereporterforgenomicdnaediting
_version_ 1724503126616047616