Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis

The paper proposes a novel approach to assess the integrity of Electrical Insulation Systems (EIS) by evaluating the response of the Transient Voltage Signature Analysis (VSA) to voltage source inverters correlated with changes in the Insulation Capacitance (IC). The involved model structures are de...

Full description

Bibliographic Details
Main Authors: Nadia Radja, M’hemed Rachek, Soraya Nait Larbi
Format: Article
Language:English
Published: MDPI AG 2018-05-01
Series:Machines
Subjects:
Online Access:http://www.mdpi.com/2075-1702/6/2/21
id doaj-7117a266dddc433c802b797a76cafd76
record_format Article
spelling doaj-7117a266dddc433c802b797a76cafd762020-11-24T20:53:38ZengMDPI AGMachines2075-17022018-05-01622110.3390/machines6020021machines6020021Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature AnalysisNadia Radja0M’hemed Rachek1Soraya Nait Larbi2Department of Electrical Engineering, Mouloud Mammeri University, BP 15000 Tizi-Ouzou, AlgeriaDepartment of Electrical Engineering, Mouloud Mammeri University, BP 15000 Tizi-Ouzou, AlgeriaDepartment of Electrical Engineering, Mouloud Mammeri University, BP 15000 Tizi-Ouzou, AlgeriaThe paper proposes a novel approach to assess the integrity of Electrical Insulation Systems (EIS) by evaluating the response of the Transient Voltage Signature Analysis (VSA) to voltage source inverters correlated with changes in the Insulation Capacitance (IC). The involved model structures are derived from the in-situ estimation of high-frequency electromagnetic RLMC lumped network parameters. Different physical phenomena such as inductive and capacitive effects, as well as skin and proximity effects are combined. To account for these phenomena, we use an approach based on equivalent multi-transmission line electric circuits with distributed parameters (R: resistances, L, M: self and mutual inductances, and C: capacitances) which are frequency-dependent. Using the finite element method, firstly the turn-to-ground and turn-to-turn capacitance parameters are performed by solving an electrostatic model with a floating electric potential approach, and secondly, the resistance and self/mutual inductances are computed from the strongly coupled magneto-harmonic and total current density equations, including the conduction and displacement eddy current densities. The sensitivity of the capacitances is measured according to insulation thickness, and the dielectric properties are adopted to test the degradation order scenarios of the EIS and comparing their time and frequency domains of transient voltage waveform behavior with respect to healthy assessed insulation systems.http://www.mdpi.com/2075-1702/6/2/21electromagnetic analysisfinite elementfourier transformerinsulation testingRLC-circuitsskin and proximity effectsvoltage wave
collection DOAJ
language English
format Article
sources DOAJ
author Nadia Radja
M’hemed Rachek
Soraya Nait Larbi
spellingShingle Nadia Radja
M’hemed Rachek
Soraya Nait Larbi
Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis
Machines
electromagnetic analysis
finite element
fourier transformer
insulation testing
RLC-circuits
skin and proximity effects
voltage wave
author_facet Nadia Radja
M’hemed Rachek
Soraya Nait Larbi
author_sort Nadia Radja
title Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis
title_short Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis
title_full Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis
title_fullStr Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis
title_full_unstemmed Non-Destructive Testing for Winding Insulation Diagnosis Using Inter-Turn Transient Voltage Signature Analysis
title_sort non-destructive testing for winding insulation diagnosis using inter-turn transient voltage signature analysis
publisher MDPI AG
series Machines
issn 2075-1702
publishDate 2018-05-01
description The paper proposes a novel approach to assess the integrity of Electrical Insulation Systems (EIS) by evaluating the response of the Transient Voltage Signature Analysis (VSA) to voltage source inverters correlated with changes in the Insulation Capacitance (IC). The involved model structures are derived from the in-situ estimation of high-frequency electromagnetic RLMC lumped network parameters. Different physical phenomena such as inductive and capacitive effects, as well as skin and proximity effects are combined. To account for these phenomena, we use an approach based on equivalent multi-transmission line electric circuits with distributed parameters (R: resistances, L, M: self and mutual inductances, and C: capacitances) which are frequency-dependent. Using the finite element method, firstly the turn-to-ground and turn-to-turn capacitance parameters are performed by solving an electrostatic model with a floating electric potential approach, and secondly, the resistance and self/mutual inductances are computed from the strongly coupled magneto-harmonic and total current density equations, including the conduction and displacement eddy current densities. The sensitivity of the capacitances is measured according to insulation thickness, and the dielectric properties are adopted to test the degradation order scenarios of the EIS and comparing their time and frequency domains of transient voltage waveform behavior with respect to healthy assessed insulation systems.
topic electromagnetic analysis
finite element
fourier transformer
insulation testing
RLC-circuits
skin and proximity effects
voltage wave
url http://www.mdpi.com/2075-1702/6/2/21
work_keys_str_mv AT nadiaradja nondestructivetestingforwindinginsulationdiagnosisusinginterturntransientvoltagesignatureanalysis
AT mhemedrachek nondestructivetestingforwindinginsulationdiagnosisusinginterturntransientvoltagesignatureanalysis
AT sorayanaitlarbi nondestructivetestingforwindinginsulationdiagnosisusinginterturntransientvoltagesignatureanalysis
_version_ 1716796730309083136