Experimental investigation of stabilization of flowing water temperature with a water-PCM heat exchanger

Experiments have been carried out in order to investigate the stabilization of water temperature with a water-PCM heat exchanger. The water-PCM heat exchanger was of a rather simple design. It was a round tube, through which the water flowed, surrounded with an annular layer of PCM. The heat exchan...

Full description

Bibliographic Details
Main Authors: Charvat Pavel, Stetina Josef, Pech Ondrej, Klimes Lubomir, Ostry Milan
Format: Article
Language:English
Published: EDP Sciences 2014-03-01
Series:EPJ Web of Conferences
Online Access:http://dx.doi.org/10.1051/epjconf/20146702046