Fatal Injury of the Small Intestine during Retropubic Sling Placement

We describe a case of injury of the small intestine in a patient who underwent placement of Align R retropubic urethral support system (BARD). Absence of characteristic symptoms of the bowel injury and peritonitis led to a rapid development of sepsis, multiple organ failure, and death. Although the...

Full description

Bibliographic Details
Main Authors: P. Kascak, B. Kopcan
Format: Article
Language:English
Published: Hindawi Limited 2015-01-01
Series:Case Reports in Obstetrics and Gynecology
Online Access:http://dx.doi.org/10.1155/2015/164545