Aqueous particle generation with a 3D printed nebulizer

<p>In this study, we describe the design and testing of a high-output-stability, constant-liquid-feed nebulizer using the Venturi principle to generate liquid particles from solutions. This atomizer, the PRinted drOpleT Generator (PROTeGE), was manufactured using stereolithography (SLA) printi...

Full description

Bibliographic Details
Main Authors: M. Rösch, D. J. Cziczo
Format: Article
Language:English
Published: Copernicus Publications 2020-12-01
Series:Atmospheric Measurement Techniques
Online Access:https://amt.copernicus.org/articles/13/6807/2020/amt-13-6807-2020.pdf