Effects of composite scale on high temperature oxidation resistance of Fe-Cr-Ni heat resistant alloy

Fe-Cr-Ni heat resistant alloys with aluminum and silicon addition, alone and in combination, were melted using an intermediate frequency induction furnace with a non-oxidation method. By the oxidation weight gain method, the oxidation resistances of the test alloys were determined at 1,200 ìC for 50...

Full description

Bibliographic Details
Main Authors: Wang Haitao, Wang Yuqing, Yu Huashun
Format: Article
Language:English
Published: Foundry Journal Agency 2009-05-01
Series:China Foundry
Subjects:
Online Access:http://www.foundryworld.com/uploadfile/200912131640359.pdf