Broken Bar Fault Detection in IM Operating Under No-Load Condition
This paper presents a novel method for broken rotor bar detection in a squirrel-cage induction motor (IM). The proposed method applies a single-phase AC voltage as a test signal on motor terminals, resulting in a stator backward-rotating magnetic field. The field ultimately causes additional curre...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Stefan cel Mare University of Suceava
2016-11-01
|
Series: | Advances in Electrical and Computer Engineering |
Subjects: | |
Online Access: | http://dx.doi.org/10.4316/AECE.2016.04010 |