Cord Compression Caused by a Tangled and Warped Lumbar Catheter After Lumboperitoneal Shunt Placement

The present study reports the case of an 81-year-old woman who underwent lumboperitoneal shunt (LPS) placement for idiopathic normal-pressure hydrocephalus. After LPS placement, the patient presented with radicular pain. A computed tomography scan revealed that the intradural lumbar catheter was tan...

Full description

Bibliographic Details
Main Authors: Kanako Sato, Toshiki Endo, Hiroyuki Sakata, Tomoo Inoue, Kuniyasu Niizuma, Teiji Tominaga
Format: Article
Language:English
Published: Korean Spinal Neurosurgery Society 2019-06-01
Series:Neurospine
Subjects:
Online Access:http://www.e-neurospine.org/upload/pdf/ns-1836114-057.pdf