Optimal configuration of a micro-earthquake network
This study simulates automatic event detection and location performance of a micro-earthquake network centred around a future power plant site in Finland, Fennoscandian Shield. Simulation of the event location capability is based on a relationship derived between event magnitude and maximum detectio...