Thermophysical characteristics of low density autoclaved aerated concrete and their influence on durability of exterior walls of buildings
The paper presents the results of experimental studies of thermophysical characteristics of autoclaved aerated concrete with density of 400 and 500 kg/m3. The dependence of thermal conductivity on temperature and humidity was determined. The boundary humidities were set for which ice is either not...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Peter the Great St. Petersburg Polytechnic University
2015-03-01
|
Series: | Инженерно-строительный журнал |
Subjects: | |
Online Access: | http://engstroy.spb.ru/eng/index_2015_02/05.html |