Central Venous Line Insertion Revealing Partial Anomalous Pulmonary Venous Return: Diagnosis and Management
Central venous line malposition is a well-known complication of line insertion. Rarely, it can be mal-positioned in an anomalous pulmonary vein. We present an unusual case of a 56-year-old woman that was found to have partial anomalous pulmonary venous return on central venous line insertion. In thi...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Hindawi Limited
2017-01-01
|
Series: | Case Reports in Critical Care |
Online Access: | http://dx.doi.org/10.1155/2017/3218063 |