Quantification of the Static Equivalent Pressure of Gas Phase Detonations in Pipes at the DDT, in the Region of Stable Detonation (if any) and at the Reflection Point

In order to establish guidelines for detonation pressure proof pipe design, experiments in 48.3x2.6 and 114.3x3.6 pipes (outer diameter [mm] x wall thickness [mm]) were conducted, in which deflagrative explosions of stoichiometric C2H4/air-mixtures at 20 °C underwent the transition to detonation. In...

Full description

Bibliographic Details
Main Authors: H.P. Schildberg, G. Sudano, C. Streuber
Format: Article
Language:English
Published: AIDIC Servizi S.r.l. 2013-05-01
Series:Chemical Engineering Transactions
Online Access:https://www.cetjournal.it/index.php/cet/article/view/6882