Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton
This paper proposes a method and instruments for assessing the build quality and the technical condition of an electric gear actuator for an exoskeleton based on determining its starting torque as one of the main indicators of the level of degradation of its components. Existing methods are mainly b...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institut za istrazivanja i projektovanja u privredi
2019-01-01
|
Series: | Istrazivanja i projektovanja za privredu |
Subjects: | |
Online Access: | https://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2019/1451-41171903386B.pdf |
id |
doaj-170b9afd557d4fb58882f6b6e8eafc45 |
---|---|
record_format |
Article |
spelling |
doaj-170b9afd557d4fb58882f6b6e8eafc452021-04-02T11:11:51ZengInstitut za istrazivanja i projektovanja u privrediIstrazivanja i projektovanja za privredu1451-41171821-31972019-01-011733863941451-41171903386BDevelopment of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeletonBelogusev Vladimir0Egorov Aleksey1Volga State University of Technology, Institute of Mechanics and Machine Building, Russian FederationVolga State University of Technology, Institute of Mechanics and Machine Building, Russian FederationThis paper proposes a method and instruments for assessing the build quality and the technical condition of an electric gear actuator for an exoskeleton based on determining its starting torque as one of the main indicators of the level of degradation of its components. Existing methods are mainly based on identifying starting torque with the help of additional devices that require involvement of an operator in the measurement process, which increases its time and labor costs and makes it difficult to be automated. As opposed to the existing methods and instruments, the method and hardware-software complex developed in this study allow automating the measurement process, does not require expensive equipment, and has potential for conducting technical state control without dismounting an actuator from an exoskeleton. In the experimental part of this paper, the proposed method and tools were evaluated on the basis of electric actuators with reduction gears for an electromechanical orthosis of a lower limb exoskeleton. According to the experimental results, the discrepancy between the values of starting torque obtained separately by an existing method and by the proposed one is within 1.8%, which confirms the efficacy and applicability of the developed method for monitoring the technical condition of electric actuators for exoskeletons both at the stage of their production and during their operation.https://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2019/1451-41171903386B.pdfstarting torquereduction gear-motorexoskeleton efficiency controlelectric drive efficiencyexoskeleton actuator |
collection |
DOAJ |
language |
English |
format |
Article |
sources |
DOAJ |
author |
Belogusev Vladimir Egorov Aleksey |
spellingShingle |
Belogusev Vladimir Egorov Aleksey Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton Istrazivanja i projektovanja za privredu starting torque reduction gear-motor exoskeleton efficiency control electric drive efficiency exoskeleton actuator |
author_facet |
Belogusev Vladimir Egorov Aleksey |
author_sort |
Belogusev Vladimir |
title |
Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton |
title_short |
Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton |
title_full |
Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton |
title_fullStr |
Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton |
title_full_unstemmed |
Development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton |
title_sort |
development of a method and instruments to assess the build quality and the technical condition of an electric gear actuator for an electromechanical orthosis of a lower limb exoskeleton |
publisher |
Institut za istrazivanja i projektovanja u privredi |
series |
Istrazivanja i projektovanja za privredu |
issn |
1451-4117 1821-3197 |
publishDate |
2019-01-01 |
description |
This paper proposes a method and instruments for assessing the build quality and the technical condition of an electric gear actuator for an exoskeleton based on determining its starting torque as one of the main indicators of the level of degradation of its components. Existing methods are mainly based on identifying starting torque with the help of additional devices that require involvement of an operator in the measurement process, which increases its time and labor costs and makes it difficult to be automated. As opposed to the existing methods and instruments, the method and hardware-software complex developed in this study allow automating the measurement process, does not require expensive equipment, and has potential for conducting technical state control without dismounting an actuator from an exoskeleton. In the experimental part of this paper, the proposed method and tools were evaluated on the basis of electric actuators with reduction gears for an electromechanical orthosis of a lower limb exoskeleton. According to the experimental results, the discrepancy between the values of starting torque obtained separately by an existing method and by the proposed one is within 1.8%, which confirms the efficacy and applicability of the developed method for monitoring the technical condition of electric actuators for exoskeletons both at the stage of their production and during their operation. |
topic |
starting torque reduction gear-motor exoskeleton efficiency control electric drive efficiency exoskeleton actuator |
url |
https://scindeks-clanci.ceon.rs/data/pdf/1451-4117/2019/1451-41171903386B.pdf |
work_keys_str_mv |
AT belogusevvladimir developmentofamethodandinstrumentstoassessthebuildqualityandthetechnicalconditionofanelectricgearactuatorforanelectromechanicalorthosisofalowerlimbexoskeleton AT egorovaleksey developmentofamethodandinstrumentstoassessthebuildqualityandthetechnicalconditionofanelectricgearactuatorforanelectromechanicalorthosisofalowerlimbexoskeleton |
_version_ |
1724165421271089152 |