Comparison of the outcomes of the sling technique using a commercial and hand-made polypropylene sling
PURPOSE: To compare the outcomes and costs of stress urinary incontinence (SUI) surgery using a hand-made sling (Marlex®) versus a commerciallyavailable suburethral polypropylene sling (Advantage®). MATERIALS AND METHODS: Thirty-nine women with SUI due to bladder neck hypermobility and/or sphincter...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Sociedade Brasileira de Urologia
2011-08-01
|
Series: | International Brazilian Journal of Urology |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1677-55382011000400012 |