Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets

In this work, the potential of spectroscopic techniques was studied to investigate heat-induced changes occurring during the application of thermal treatments on cod (<i>Gadus morhua L.</i>) fillets. Vacuum-packed samples were thermally treated in a water bath at 50, 60, 70 and 80 °C for...

Full description

Bibliographic Details
Main Authors: Abdo Hassoun, Janna Cropotova, Turid Rustad, Karsten Heia, Stein-Kato Lindberg, Heidi Nilsen
Format: Article
Language:English
Published: MDPI AG 2020-04-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/20/8/2410
id doaj-12abe9f565f148d9a4613b82fbf35c12
record_format Article
spelling doaj-12abe9f565f148d9a4613b82fbf35c122020-11-25T03:01:39ZengMDPI AGSensors1424-82202020-04-01202410241010.3390/s20082410Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod FilletsAbdo Hassoun0Janna Cropotova1Turid Rustad2Karsten Heia3Stein-Kato Lindberg4Heidi Nilsen5Nofima, Norwegian Institute of Food, Fisheries, and Aquaculture Research, Muninbakken 9-13, 9291 Tromsø, NorwayDepartment of Biotechnology and Food Science, Norwegian University of Science and Technology, 7941 Trondheim, NorwayDepartment of Biotechnology and Food Science, Norwegian University of Science and Technology, 7941 Trondheim, NorwayNofima, Norwegian Institute of Food, Fisheries, and Aquaculture Research, Muninbakken 9-13, 9291 Tromsø, NorwayNofima, Norwegian Institute of Food, Fisheries, and Aquaculture Research, Muninbakken 9-13, 9291 Tromsø, NorwayNofima, Norwegian Institute of Food, Fisheries, and Aquaculture Research, Muninbakken 9-13, 9291 Tromsø, NorwayIn this work, the potential of spectroscopic techniques was studied to investigate heat-induced changes occurring during the application of thermal treatments on cod (<i>Gadus morhua L.</i>) fillets. Vacuum-packed samples were thermally treated in a water bath at 50, 60, 70 and 80 °C for 5 and 10 min, and further stored for one, four, and eight days at 4 ± 1 °C before analysis. Several traditional (including cooking loss, drip loss, texture, protein solubility, protein oxidation, and color) and spectroscopic (fluorescence and diffuse reflectance hyperspectral imaging) measurements were conducted on the same samples. The results showed a decrease in fluorescence intensity with increasing cooking temperature and storage time, while the impact of cooking time was only noticeable at low temperatures. Diffuse reflectance data exhibited a decrease in absorbance, possibly as a result of protein denaturation and increased scattering at higher cooking temperatures. Both fluorescence and diffuse reflectance data were highly correlated with color parameters, whereas moderate correlations were observed with most other traditional parameters. Support vector machine models performed better than partial least square ones for both classification of cod samples cooked at different temperatures and in prediction of the cooking temperature. The best classification result was obtained on fluorescence data, achieving an accuracy of 92.5%, while the prediction models resulted in a root mean square error of prediction of cooking temperature lower than 5°C. Overall, the classification and prediction models showed good results, indicating that spectroscopic techniques, especially fluorescence hyperspectral imaging, have a high potential for monitoring thermal treatments in cod fillets.https://www.mdpi.com/1424-8220/20/8/2410fishfluorescencecookingclassificationspectroscopystorage
collection DOAJ
language English
format Article
sources DOAJ
author Abdo Hassoun
Janna Cropotova
Turid Rustad
Karsten Heia
Stein-Kato Lindberg
Heidi Nilsen
spellingShingle Abdo Hassoun
Janna Cropotova
Turid Rustad
Karsten Heia
Stein-Kato Lindberg
Heidi Nilsen
Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets
Sensors
fish
fluorescence
cooking
classification
spectroscopy
storage
author_facet Abdo Hassoun
Janna Cropotova
Turid Rustad
Karsten Heia
Stein-Kato Lindberg
Heidi Nilsen
author_sort Abdo Hassoun
title Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets
title_short Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets
title_full Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets
title_fullStr Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets
title_full_unstemmed Use of Spectroscopic Techniques for a Rapid and Non-Destructive Monitoring of Thermal Treatments and Storage Time of Sous-Vide Cooked Cod Fillets
title_sort use of spectroscopic techniques for a rapid and non-destructive monitoring of thermal treatments and storage time of sous-vide cooked cod fillets
publisher MDPI AG
series Sensors
issn 1424-8220
publishDate 2020-04-01
description In this work, the potential of spectroscopic techniques was studied to investigate heat-induced changes occurring during the application of thermal treatments on cod (<i>Gadus morhua L.</i>) fillets. Vacuum-packed samples were thermally treated in a water bath at 50, 60, 70 and 80 °C for 5 and 10 min, and further stored for one, four, and eight days at 4 ± 1 °C before analysis. Several traditional (including cooking loss, drip loss, texture, protein solubility, protein oxidation, and color) and spectroscopic (fluorescence and diffuse reflectance hyperspectral imaging) measurements were conducted on the same samples. The results showed a decrease in fluorescence intensity with increasing cooking temperature and storage time, while the impact of cooking time was only noticeable at low temperatures. Diffuse reflectance data exhibited a decrease in absorbance, possibly as a result of protein denaturation and increased scattering at higher cooking temperatures. Both fluorescence and diffuse reflectance data were highly correlated with color parameters, whereas moderate correlations were observed with most other traditional parameters. Support vector machine models performed better than partial least square ones for both classification of cod samples cooked at different temperatures and in prediction of the cooking temperature. The best classification result was obtained on fluorescence data, achieving an accuracy of 92.5%, while the prediction models resulted in a root mean square error of prediction of cooking temperature lower than 5°C. Overall, the classification and prediction models showed good results, indicating that spectroscopic techniques, especially fluorescence hyperspectral imaging, have a high potential for monitoring thermal treatments in cod fillets.
topic fish
fluorescence
cooking
classification
spectroscopy
storage
url https://www.mdpi.com/1424-8220/20/8/2410
work_keys_str_mv AT abdohassoun useofspectroscopictechniquesforarapidandnondestructivemonitoringofthermaltreatmentsandstoragetimeofsousvidecookedcodfillets
AT jannacropotova useofspectroscopictechniquesforarapidandnondestructivemonitoringofthermaltreatmentsandstoragetimeofsousvidecookedcodfillets
AT turidrustad useofspectroscopictechniquesforarapidandnondestructivemonitoringofthermaltreatmentsandstoragetimeofsousvidecookedcodfillets
AT karstenheia useofspectroscopictechniquesforarapidandnondestructivemonitoringofthermaltreatmentsandstoragetimeofsousvidecookedcodfillets
AT steinkatolindberg useofspectroscopictechniquesforarapidandnondestructivemonitoringofthermaltreatmentsandstoragetimeofsousvidecookedcodfillets
AT heidinilsen useofspectroscopictechniquesforarapidandnondestructivemonitoringofthermaltreatmentsandstoragetimeofsousvidecookedcodfillets
_version_ 1724692736743833600